A sealant required to resist air passage between qualifying mass timber elements must comply with ASTM C920. Therefore, option C is correct. ASTM C920 is the recognized specification for elastomeric joint sealants and establishes requirements for properties such as movement capability, adhesion, cohesion, hardness, weathering, and durability.
IBC Section 703.7 differentiates between the two materials: sealants must meet ASTM C920, while adhesives must meet ASTM D3498. Option D therefore applies to an adhesive rather than a sealant. ASTM E119 is the standard fire test used to establish the fire-resistance rating of structural members and assemblies; it does not serve as the product specification for the sealant. ASTM E114 is not the applicable standard under this provision.
The stated exception is important. Section 703.7 does not require an additional sealant or adhesive where it is not a required component of the tested fire-resistance-rated assembly. Where the approved assembly or code provision does require it, however, the specified product, location, joint preparation, backing material, depth, width, and tooling must match the approved construction documents.
References/Topics: 2021 IBC Section 703.7; ASTM C920 sealants; ASTM D3498 adhesives; tested fire-resistance-rated assemblies.
===============